Magnetic & Acoustic Options for Onshore, Offshore & Subsea Applications

Inline Services is the exclusive U.S. Distributor for IK® Online Electronics Non-Intrusive Pig Signalling equipment for onshore, topside and subsea applications.  Non-intrusive pig signalling equipment can help you avoid costly downtime and associated expenses looking for a lost or stuck pig. Installed at high risk points, pig signallers allow you to remotely monitor a pigs progression in the line regardless of pipeline size, location, wall thickness or other operational challenges.

  • Inline Services is the exclusive U. S. distributor of the IK® Online Electronics 4003D MAGSIG® Magnetic Non-Intrusive Pig Signaller.  This compact signaller detects magnetic pigs in any pipeline medium, removing any uncertainty over pig passage allowing operations to continue on schedule. Minimal set up is required ensuring that time is not wasted setting up various parameters. Events are signalled as they occur via a OLED display and high brightness LEDs positioned around the perimeter of the display. The unit logs the time and date of up to 100 events. Logged events can be viewed locally via the display. Events can be transmitted to your SCADA via contact closure or 4-20ma. Two way communication can be made to read event data or make unit changes via RS485 MODBUS protocol or on your handheld Android device via Bluetooth with an Online App. Remove site configurations are available via LEO Satellite communication. Available languages of operation include English, French, Spanish and Portuguese. REQUEST A QUOTE
    • UL / CSA Class 1 Division 1 certified non-intrusive magnetic signaller for use on onshore pipelines in addition to offshore platforms and FPSOs.
    • Approval for Canadian and UL specifications hazardous area specifications
    • Quick and easy installation using ratchet straps or steel banding
    • Versatile – can be installed on any pipeline up to 60” diameter with wall thickness up to 50mm, carrying any medium and with pigs running at varying speeds
    • Details of pig passage events can be signalled remotely via operator's SCADA system
    • No location restrictions – can be located on major barrel and magnetic sensor can be supplied on a cable up to 10m long for use with buried pipelines or where access is limited.
    • Temperature range can be extended after consultation with Online.
    Power Options:• 4x Alkaline 1.5V 18Ah D cells
    (1 yr battery life)
    • 2x Lithium Thionyl Chloride 3.6V 17Ah D cells
    (1 yr battery life)
    • External supply - +21.6VDC to +26.4VDC, <1.0W
    Temperature Range:• Using External supply -50°C to +85°C
    (-58°F to +185°F)
    • Alkaline cells installed -20°C to +54°C
    (-4°F to+130°F)
    • Lithium cells installed -40°C to +85°
    (-40°F to +185°F)
    Entries:3x ¾” NPT
    Weight in Aluminum:11.5 lbs. (5.2 kg.)
    Weight in Stainless Steel:24.3 lbs. (11 kg.)
    Download 4003D Pig Signaller Datasheet

    Download 4003D Bluetooth Setup Instructions for Android
  • Inline Services is the exclusive U. S. distributor of the IK® Online Electronics ID5000A™ Ultrasonic Non-Intrusive Pig Signaller.  This ATEX rated signaller detects, signals and logs the passage of any pipeline pig, onshore and offshore. Events are signalled as they occur via a graphical display and high brightness LEDs positioned around the perimeter of the display. The unit logs the time and date of up to 99 events. Logged events can be viewed locally via the display or transmitted remotely. REQUEST A QUOTE
    • ATEX certified non-intrusive Active signaller for use on liquid filled pipelines.
    • Can also be used to confirm the location of pigs in the receiver, as an interface detector and to monitor wax build-up.
    • Quick and easy installation using ratchet straps or steel banding
    • Minimal set up required ensuring time is not lost setting up multiple parameters
    • Locator function allows for confirmation that pig pas passed isolation valve
    • Unit can be installed close to pig receiver door, allowing for easy pig recovery
    • Main housing can be mounted remotely up to 10 metres from sensor for use on buried pipelines or where access is limited
    • Temperature range can be extended after consultation with Online
    Power Options:• 15V Alkaline Non-Rechargeable Battery Pack
    (120 days battery life)
    • 12V NiMH Rechargeable Battery Pack
    (12 days battery life)
    • External supply 21.6V DC to 26.4V DC <1.0W
    Temperature Range:• Using External supply.....-20°C to +85°C
    (-4°F to +185°F)
    • Non-Rechargeable Battery Pack installed.....-20°C to +54°C
    (-4°F to +129°F)
    • NiMh Rechargeable Battery Pack installed.....-20°C to +65°C
    (-4°F to +149°F)
    Weight in Aluminum:23.1 lbs. (10.5 kg.)
    Weight in Stainless Steel:30.9 lbs. (14 kg.)
    ATEX Code:II 2 G Ex d mb IIC T5…T6
    Ingress Protection:IP66
    Download ID5000A™ Pig Signaller Datasheet
  • Inline Services is the exclusive U. S. Distributor of the IK® Online Electronics ID5001P Passive Ultrasonic Non-Intrusive Pig Signaller.  This ATEX  and IECEX rated signaller detects, signals and logs the passage of any pipeline pig, onshore and offshore. Events are signalled as they occur via a graphical display and high brightness LEDs positioned around the perimeter of the display. The unit logs the time and date of up to 99 events. Logged events can be viewed locally via the display or transmitted remotely. REQUEST A QUOTE
    • Can result in both time and cost savings during pigging operations
    • Suitable for all pig types - no transmitters or magnets are required to confirm passage or location in the receiver
    • ATEX & IECEX certified non-intrusive Passive signaller
    • Improved user interface
    • Quick and easy installation using ratchet straps or stainless steel banding
    • Suitable for gas and liquid pipelines
    • Main housing can be mounted remotely up to 10 metres from sensor for use on buried pipelines or where access is limited
    Power Options:• External Supply 25.0VDC, >2.0W
    • Battery (Alkaline) - 7x Alkaline DURACELL ID1300 Cells
    • Battery (Lithium) - 7x Lithium SAFT LS33500 Cells
    Temperature Range:• Main Housing Ambient (External Supply) -40°C to +85°C
    • Main Housing Ambient (Alkaline) -20°C to +54°C
    • Main Housing Ambient (Lithium) -40°C to +85°C
    • Sensor Ambient -55°C to +110°C
    • Maximum Allowable Pipeline Surface +150°C (refer to datasheet Note 1)
    Weight in Aluminum:17.6 lbs. (8 kg.)
    Weight in Stainless Steel:28.6 lbs. (13 kg.)
    ATEX Code:Ex II 1/2 G
    IECEx Code:Ex d ia [ia Ga] IIC T4…T6 Gb
    Ingress Protection:• Main Housing - IP66
    • Sensor - IP68
    Download ID5001P Pig Signaller Datasheet